SOLUTIONS FOR TEKTRONIX EQUIPMENT


Measure Bode Plots and PSRR with Tektronix 5/6 Series MSO and Picotest Injectors

 

 Adding TDR Capability to Tek Oscilloscopes
Low cost, portable, oscilloscope gets high speed TDR/TDT

Tektronix TDR Setup File

Solution Brochure - Adding TDR Capability to Tek Oscilloscopes

Solution Brochure - Measuring Cable Losses

Picotest Products You’ll Need:

Picotest J2151A PerfectPulse® Fast Edge Signal Generator
Add to Cart
 

 

 2-Port Shunt-Through Measurement on an Oscilloscope
The 2-port shunt-through impedance measurement is the key to testing low impedance components and PDNs

Solution Brochure

Picotest Products You’ll Need:

J2161A 2-Way Wideband Active Splitter
Add to Cart
BNCJ/BNCJ-12INCH Two (2) PDN Cables® (12" BNC-BNC Connector)
Add to Cart
BNCJ/SMAJ-24INCH Two (2) PDN Cables® (24" BNC-SMA Connector)
Add to Cart
BNCJ/BNCJ-1000 One (1) PDN Cable® (1m BNC-BNC Connector)
Add to Cart
J2102B-BNC Common Mode Transformer – BNC Connectors
Add to Cart
OR
J2102B-N Common Mode Transformer – N Connectors
Add to Cart
OPTIONAL
PITK01 Parts Kit for Power Integrity Training
Add to Cart
P2130A DC Blocker 500Hz - 8GHz
Add to Cart
VRTS3 Distributed System Demo Board
Add to Cart
P2102A 2-Port Probe
More Info
 


Bode Plot & PSRR Testing
Stability made via a Bode plot and Power Supply Rejection Ratio (PSRR) measurements are essential to assessing power supply performance

Application Note

Measuring the Control Loop Response of a Power Supply Using an Oscilloscope

Solution Brochures

Bode Plot Solution Brochure
PSRR Solution Brochure
FRA Bundle Solution Brochure

Picotest Products You’ll Need:

FRAB1P5 including: J2100A Injection Transformer, J2120A Line Injector, VRTS1P51 Voltage Regulator Test Standard V1.51 Add to Cart
Demo Board VRTS3 Distributed System Demo Board Add to Cart
BNCJ/BNCJ-12INCH BNCJ/BNCJ-12INCH Two (2) PDN Cables® (12" BNC-BNC Connector) Add to Cart
Optional J2110A Solid-State Injection Transformer and Line Injector Add to Cart
Optional
OL000110 PML 111O Passive 10:1 Probe
Add to Cart
 


Injector Supports Power Inductor Testing under Bias
Enables accurate shunt-through inductance measurement of power inductors at various bias levels - up to and including saturation currents up to 125ADC

Solution Brochure

Application Note

Picotest Products You’ll Need:

J2131ABUNDLE J2131A DC Bias Source, P9610A Power Supply, J2113A Differential Amp,  Three (3) PDN Cables (Two (2) 0.5m BNC-SMA cables and One (1) 0.25m BNC-BNC cable) The bundle enables the 2-port shunt through measurement for your VNA or oscilloscope with FRA features * Add to Cart
* Biased Inductor Measurement Requirements and Notes: The J2131A uses the 2-port shunt through test configuration to perform the inductor measurement. It cannot perform the measurement by itself.
The 2-port shunt through measurement REQUIRES a ground loop breaker, such as the J2113A.
 


PSRR Injector
DC-DC Converter Input Impedance Testing with the Tektronix 5/6 Series MSO

Solution Brochure


Picotest Products You’ll Need:

J2121A J2121A High Power Line Injector Add to Cart
SMAJ/SMAJ-1000 Two (2) PDN Cables, 1 Meter Each, SMA-SMA Add to Cart
 

Tektronix Webinars and Presentations

Best Practices for Interpreting Power Integrity Measurements.
Designing Power for Sensitive Circuits (DGCON 2019)
FRA Measurements for Power Electronics
Power Integrity



  • 电话:0512-68086023
  • 传真:0512-68086025#59
  • 邮箱:info@picotest.com.cn
  • 地址: 江苏省苏州市吴中区金枫路216号东创科技园B3号楼308